BJFMB - FLEX GLOW HI-HIDING WHITE 300
- MSDS: BJFMB
- Manufacturer: PARKER PAINT
- Product Name: FLEX GLOW HI-HIDING WHITE 300
- National Stock Number: 8010-00N012578
Product Identification
Product ID:FLEX GLOW HI-HIDING WHITE 300
MSDS Date:01/25/1989
FSC:8010
NIIN:00N012578
MSDS Number: BJFMB
Responsible Party
TACOMA, WA 98411-0047
US
Emergency Phone: 206-473-1122
Info Phone: 206-473-1122
Preparer: J BURNWORTH
Cage: 9H480
Contractor
Telephone: 253-473-1122
Cage: 9H480
Ingredients
AMMONIA (SARA III)
CAS: 7664-41-7
RTECS: BO0875000
Fraction By Weight: 0.11%
OSHA PEL 50 PPM
ACGIH TLV: 25 PPM/35 STEL; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:(SHORT TERM) OVER EXPOSURE MAY
CAUSE HEADACHE, NAUSEA, SKIN AND EYE IRRITATION. CHRONIC:(LONG
TERM) UNPROTECTED OVER EXPOSURE TO MISTS FROM SPRAY APPLICATION MAY
CAUSE LUNG DISEASE (SILICOSIS).
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:INHAL:INHAL OF HIGH CONC OF VAPORS MAY CAUSE
HDCH,NAUS&IRRIT OF NOSE,THROAT,&LUNGS.SKIN&EYE:EYE CONT MAY CAUSE
IRRIT/BURNING OF EYES.RPTD LIQ CONT MAY CAUSE SKIN
IRRIT&DERMAT.INGEST:SWALLOWING CAN CAU SE GI
IRRIT,NAUS,VOMIT&DIARR.VOMIT CAN RESULT IN ASPIR OF MATL IN LUNGS
WHICH CAN CAUSE CHEMICAL PNEUMONITIS.
Medical Cond Aggravated by Exposure:NONE KNOWN AT THIS TIME.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR.IF BREATHING HAS STOPPED,APPLY
ARTIFICIAL RESPIRATION.CONSULT MD.EYE:WASH EYES WITH CLEAN WATER
FOR AT LEAST 15 MINUTES.CONSULT MD.SKIN:WASH AFFECTED AREAS WITH
SOAP AND WATE R.REMOVE CONTAMINATED CLOTHING.CONSULT
MD.INGEST:DRINK 1 OR 2 GLASSES OF WATER TO DILUTE.CONSULT MD OR
POISON CONTROL CENTER IMMEDIATELY.
Fire Fighting
Extinguishing Media:FOAM, ALCOHOL FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:FULL PROTECTIVE EQUIPMENT, INCLUDING A SELF-
CONTAINED BREATHING APPARATUS IS RECOMMENDED TO PROTECT FIRE
FIGHTERS FROM ANY HAZARDOUS COMBUSTION PRODUCTS.
Unusual Fire/Explosion Hazard:WATER MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD UP AND EXPLOSION WHEN EXPOSED
TO EXTREME HEAT.
Accidental Release
Spill Release Procedures:VENTILATE AREA.PREVENT SKIN AND EYE CONTACT
AND BREATHING OF VAPOR.CONTAIN AND REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE ABOVE 200F.
Other Precautions:DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF
CHILDREN.
Exposure Controls
Respiratory Protection:NOT REQUIRED FOR BRUSH AND ROLL APPLICATION,FOR
SPRAY APPLICATION,WEAR A PROPERLY FITTED NIOSH/MSHA (TC-23C)
APPROVED VAPOR/PARTICULATE RESPIRATOR UNTIL ALL VAPORS AND SPRAY
MIST ARE EXHAUSTED.
Ventilation:PROVIDE SUFF VENT IN VOLUME&PATTERN TO KEEP AIR CONTAM CONC
BELOW APPLIC OSHA PEL/ACGIH TLV OCCUPATIONAL EXPOS LIM.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOGGLES,FACESHLD OPTNL .
Other Protective Equipment:COVERALLS,GLOVES&HOOD ARE RECOMND DURING
SPRAY APPLIC,PROT CREAMS MAY BE USED FOR EASE OF CLEAN-UP,NOT FOR
PROTECTION.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING THE RESTROOM.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Density:
Evaporation Rate & Reference:
Appearance and Odor:WHITE COLORED LIQUID WITH AMMONIACAL ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN AT THIS TIME.
Stability Condition to Avoid:DO NOT HEAT ABOVE 200F.
Hazardous Decomposition Products:NONE KNOWN AT THIS TIME.
Disposal
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS.ABSORB LARGE SPILLS WITH SAND,CLAY,OR DIATOMACEOUS
EARTH.DISPOSE IN ACCORDANCE WITH LOCAL,STATE AND FEDERAL DISPOSAL
REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.